30
30
RFJA-12B/230V RFJA-12B/24VDC
R
FJ
A
-
1
2
B
RFJA-12B
RF
J
A
-
1
2
B
RFJA-12B/230V
M
N
L
M
12-24 V DC
+
-
- +
RFJA-12B/230V RFJA-12B/24VDC
60mm
21mm
60mm
13mm
RFJA-12B/230V RFJA-12B/24VDC
Wiring
RF shutter ACTUATOR is used for controlling shutter engines, window shutters, garage gates, etc.
RFJA-12B/230V: switches 230V AC electric engines, which are controlled in two directions and have built-in
protector terminal switch.
- the time function of the relay “remembers” the time of closing and opening the blinds
RFJA-12B/24 V DC: controls particularly shutters and blinds installed inside the window (12-24V DC electric
engines), with built- in terminal switch, where direction of the motion is controlled by
switching polarity
- the time function of the relay “remembers” the time of closing and opening the blinds
- contactless and noise-free switching
each actuator can be controlled by up to 32 channels (1 channel is represented by 1 button on the wireless wall
switch button, keychain or the RF Touch-W / RF Touch-B unit).
LED indicator of the device status on the front panel
for programming and manual control, press the Prog button
for mounting in an installation box (such as KU-68) or to be installed into non-conducting covers of unit engines
possibility to assign receivers to the RF Control system
!
!
!
!
!
!
!
!
Example of use
Device description
1. When the control button is pressed for less than 2 seconds, shutters move up ( ) or down ( ).
2. When the control button is pressed for more than 2 seconds, shutters move up ( ) or down ( )
until reaching the nal position.
EAN code
RFJA-12B/230V: 8595188137010 / RFJA-12B/24V DC: 8595188140614
* Identical with supply voltage
** For more information, see p. 48
Function description
RF receiver: Shutter actuator RFJA-12B/230V, RFJA-12B/24VDC
Supply voltage:
Apparent input:
Dissipated power:
Power without load:
Power under load:
Supply voltage tolerance:
Output
Number of contacts:
Rated current:
Permanent current:
Switching power:
Peak current:
Switching voltage:
Switching output voltage*:
Mechanical service life:
Electrical service life (AC1):
Control:
RF, by command from transmitter:
Manual control:
Range in free space:
Other data:
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Terminals:
Length of terminals:
Dimensions:
Weight:
Related standards:
Technical parameters
Phase conductor
Neutral conductor
Device status
indicator – LED
Program button
(manual control)
Output relay contacts
12-24 V DC
x
x
0.5 W
25 W
x
x
1 A
x
1.5 A
x
12-24 V DC*
x
x
868 MHz
PROG (STOP, , STOP, )
up to 100 m
-15 to + 50 °C
any **
free at lead-in wires
IP 30
III.
2
CY wire, cross section 4x0.75 mm
2
90 mm
49 x 49 x 21 mm 49 x 49 x 13 mm
46 g 22 g
EN 60669, EN 300 220, EN 301 489 RTTE Directives, Gov. Reg.
No.426/2000 Sb. (Directive 1999/EC)
230 V AC / 50 - 60 Hz
7 VA / cos φ = 0.1
0.7 W
x
x
2 x switching (AgSnO
2
)
8 A / A C1
x
2000 VA / AC1
10 A / <3 s
250 V AC1
x
1x10
7
1x10
5
+10 -15 %
CONTROL
ELEMENTS
sun
01 . 01 .1 2
12:54
Lamp